1.
Phys Med Biol ; 69(9)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38537289

RESUMEN

Objective.Four-dimensional computed tomography (4DCT) imaging consists in reconstructing a CT acquisition into multiple phases to track internal organ and tumor motion. It is commonly used in radiotherapy treatment planning to establish planning target volumes. However, 4DCT increases protocol complexity, may not align with patient breathing during treatment, and lead to higher radiation delivery.Approach.In this study, we propose a deep synthesis method to generate pseudo respiratory CT phases from static images for motion-aware treatment planning. The model produces patient-specific deformation vector fields (DVFs) by conditioning synthesis on external patient surface-based estimation, mimicking respiratory monitoring devices. A key methodological contribution is to encourage DVF realism through supervised DVF training while using an adversarial term jointly not only on the warped image but also on the magnitude of the DVF itself. This way, we avoid excessive smoothness typically obtained through deep unsupervised learning, and encourage correlations with the respiratory amplitude.Main results.Performance is evaluated using real 4DCT acquisitions with smaller tumor volumes than previously reported. Results demonstrate for the first time that the generated pseudo-respiratory CT phases can capture organ and tumor motion with similar accuracy to repeated 4DCT scans of the same patient. Mean inter-scans tumor center-of-mass distances and Dice similarity coefficients were 1.97 mm and 0.63, respectively, for real 4DCT phases and 2.35 mm and 0.71 for synthetic phases, and compares favorably to a state-of-the-art technique (RMSim).Significance.This study presents a deep image synthesis method that addresses the limitations of conventional 4DCT by generating pseudo-respiratory CT phases from static images. Although further studies are needed to assess the dosimetric impact of the proposed method, this approach has the potential to reduce radiation exposure in radiotherapy treatment planning while maintaining accurate motion representation. Our training and testing code can be found athttps://github.com/cyiheng/Dynagan.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/radioterapia , Movimiento , Movimiento (Física) , Tomografía Computarizada Cuatridimensional/métodos , Respiración , Planificación de la Radioterapia Asistida por Computador/métodos
2.
Phys Med Biol ; 69(9)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38537287

RESUMEN

Objective.Online magnetic resonance imaging (MRI) guidance could be especially beneficial for pencil beam scanned (PBS) proton therapy of tumours affected by respiratory motion. For the first time to our knowledge, we investigate the dosimetric impact of respiratory motion on MRI-guided proton therapy compared to the scenario without magnetic field.Approach.A previously developed analytical proton dose calculation algorithm accounting for perpendicular magnetic fields was extended to enable 4D dose calculations. For two geometrical phantoms and three liver and two lung patient cases, static treatment plans were optimised with and without magnetic field (0, 0.5 and 1.5 T). Furthermore, plans were optimised using gantry angle corrections (0.5 T +5° and 1.5 T +15°) to reproduce similar beam trajectories compared to the 0 T reference plans. The effect of motion was then considered using 4D dose calculations without any motion mitigation and simulating 8-times volumetric rescanning, with motion for the patient cases provided by 4DCT(MRI) data sets. Each 4D dose calculation was performed for different starting phases and the CTV dose coverageV95%and homogeneityD5%-D95%were analysed.Main results.For the geometrical phantoms with rigid motion perpendicular to the beam and parallel to the magnetic field, a comparable dosimetric effect was observed independent of the magnetic field. Also for the five 4DCT(MRI) cases, the influence of motion was comparable for all magnetic field strengths with and without gantry angle correction. On average, the motion-induced decrease in CTVV95%from the static plan was 17.0% and 18.9% for 1.5 T and 0.5 T, respectively, and 19.9% without magnetic field.Significance.For the first time, this study investigates the combined impact of magnetic fields and respiratory motion on MR-guided proton therapy. The comparable dosimetric effects irrespective of magnetic field strength indicate that the effects of motion for future MR-guided proton therapy may not be worse than for conventional PBS proton therapy.


Asunto(s)
Neoplasias Pulmonares , Terapia de Protones , Humanos , Terapia de Protones/métodos , Movimiento (Física) , Radiometría/métodos , Protones , Imagen por Resonancia Magnética/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia
3.
Phys Med ; 120: 103323, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38461635

RESUMEN

PURPOSE: We investigated interplay effects and treatment time (TT) in scanned proton therapy for lung cancer patients. We compared free-breathing (FB) approaches with multiple rescanning strategies and respiratory-gating (RG) methods with various gating widths to identify the superior irradiation technique. METHODS: Plans were created with 4/1, 2/2, and 1/4 layered/volume rescans of FB (L4V1, L2V2, and L1V4), and 50%, 30%, and 10% gating widths of the total respiratory curves (G50, G30, and G10) of the RG plans with L4V1. We calculated 4-dimensional dynamic doses assuming a constant sinusoidal curve for six irradiation methods. The reconstructed doses per fraction were compared with planned doses in terms of dose differences in 99% clinical-target-volume (CTV) (ΔD99%), near-maximum dose differences (ΔD2%) at organs-at-risk (OARs), and TT. RESULTS: The mean/minimum CTV ΔD99% values for FB were -1.0%/-4.9%, -0.8%/-4.3%, and -0.1%/-1.0% for L4V1, L2V2, and L1V4, respectively. Those for RG were -0.3%/-1.7%, -0.1%/-1.0%, and 0.0%/-0.5% for G50, G30, and G10, respectively. The CTV ΔD99% of the RGs with less than 50% gate width and the FBs of L1V4 were within the desired tolerance (±3.0%), and the OARs ΔD2% for RG were lower than those for FB. The mean TTs were 90, 326, 824, 158, 203, and 422 s for L4V1, L2V2, L1V4, G50, G30, and G10, respectively. CONCLUSIONS: FB (L4V1) is the most efficient treatment, but not necessarily the optimal choice due to interplay effects. To satisfy both TT extensions and interplay, RG with a gate width as large as possible within safety limits is desirable.


Asunto(s)
Neoplasias Pulmonares , Terapia de Protones , Humanos , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Respiración , Dosificación Radioterapéutica , Tomografía Computarizada Cuatridimensional/métodos
4.
Phys Med Biol ; 69(7)2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38452385

RESUMEN

Objective. To combat the motion artifacts present in traditional 4D-CBCT reconstruction, an iterative technique known as the motion-compensated simultaneous algebraic reconstruction technique (MC-SART) was previously developed. MC-SART employs a 4D-CBCT reconstruction to obtain an initial model, which suffers from a lack of sufficient projections in each bin. The purpose of this study is to demonstrate the feasibility of introducing a motion model acquired during CT simulation to MC-SART, coined model-based CBCT (MB-CBCT).Approach. For each of 5 patients, we acquired 5DCTs during simulation and pre-treatment CBCTs with a simultaneous breathing surrogate. We cross-calibrated the 5DCT and CBCT breathing waveforms by matching the diaphragms and employed the 5DCT motion model parameters for MC-SART. We introduced the Amplitude Reassignment Motion Modeling technique, which measures the ability of the model to control diaphragm sharpness by reassigning projection amplitudes with varying resolution. We evaluated the sharpness of tumors and compared them between MB-CBCT and 4D-CBCT. We quantified sharpness by fitting an error function across anatomical boundaries. Furthermore, we compared our MB-CBCT approach to the traditional MC-SART approach. We evaluated MB-CBCT's robustness over time by reconstructing multiple fractions for each patient and measuring consistency in tumor centroid locations between 4D-CBCT and MB-CBCT.Main results. We found that the diaphragm sharpness rose consistently with increasing amplitude resolution for 4/5 patients. We observed consistently high image quality across multiple fractions, and observed stable tumor centroids with an average 0.74 ± 0.31 mm difference between the 4D-CBCT and MB-CBCT. Overall, vast improvements over 3D-CBCT and 4D-CBCT were demonstrated by our MB-CBCT technique in terms of both diaphragm sharpness and overall image quality.Significance. This work is an important extension of the MC-SART technique. We demonstrated the ability ofa priori5DCT models to provide motion compensation for CBCT reconstruction. We showed improvements in image quality over both 4D-CBCT and the traditional MC-SART approach.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Humanos , Proyectos Piloto , Tomografía Computarizada Cuatridimensional/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física) , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Fantasmas de Imagen , Algoritmos
5.
Comput Biol Med ; 171: 108145, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38442553

RESUMEN

Four-dimensional conebeam computed tomography (4D CBCT) is an efficient technique to overcome motion artifacts caused by organ motion during breathing. 4D CBCT reconstruction in a single scan usually divides projections into different groups of sparsely sampled data based on the respiratory phases. The reconstructed images within each group present poor image quality due to the limited number of projections. To improve the image quality of 4D CBCT in a single scan, we propose a novel reconstruction scheme that combines prior knowledge with motion compensation. We apply the reconstructed images of the full projections within a single routine as prior knowledge, providing structural information for the network to enhance the restoration structure. The prior network (PN-Net) is proposed to extract features of prior knowledge and fuse them with the sparsely sampled data using an attention mechanism. The prior knowledge guides the reconstruction process to restore the approximate organ structure and alleviates severe streaking artifacts. The deformation vector field (DVF) extracted using deformable image registration among different phases is then applied in the motion-compensated ordered-subset simultaneous algebraic reconstruction algorithm to generate 4D CBCT images. Proposed method has been evaluated using simulated and clinical datasets and has shown promising results by comparative experiment. Compared with previous methods, our approach exhibits significant improvements across various evaluation metrics.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Respiración , Fantasmas de Imagen , Algoritmos , Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física)
6.
Ann Otol Rhinol Laryngol ; 133(4): 441-448, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38321924

RESUMEN

OBJECTIVE: Primary hyperparathyroidism (PHPT) affects approximately 0.86% of the population, with surgical resection as the treatment of choice. A 4D computed tomography (CT) is a highly effective tool in localizing parathyroid adenomas; however, there is currently no defined role for 4D CT when stratified against ultrasonography (USG) and nuclear medicine Technetium Sestamibi SPECT/CT (SES) imaging. STUDY DESIGN: Retrospective Study. SETTING: University Hospital. METHODS: All patients who underwent parathyroidectomy for PHPT between 2014 and 2019 at a single institution were reviewed. Patients who had a 4D CT were included. We compared outcomes of 4D CT as a second line imaging modality to those of USG and SES as first line modalities. An imaging algorithm was proposed based on these findings. RESULTS: There were 84 patients identified who had a 4D CT after unsuccessful first line imaging. A 4D CT localized parathyroid adenoma to the correct quadrant in 64% of cases, and to the correct laterality in 75% of cases. Obese patients had significantly lower rates of adenoma localization with USG (33.4%), compared to non-obese patients (67.5%; P = .006). In determining multigland disease the sensitivity of 4D CT was 86%, while the specificity was 87%. CONCLUSIONS: A 4D CT has impressive rates of accurate localization of parathyroid adenomas; however due to the radiation exposure involved, it should remain a second line imaging modality. PHPT patients should first be evaluated with USG, with 4D CT used if this is unsuccessful and patients are greater than 40 years old, have a high BMI, or are having revision surgery.


Asunto(s)
Hiperparatiroidismo Primario , Neoplasias de las Paratiroides , Humanos , Adulto , Neoplasias de las Paratiroides/diagnóstico por imagen , Neoplasias de las Paratiroides/cirugía , Glándulas Paratiroides , Tomografía Computarizada Cuatridimensional/métodos , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/cirugía , Estudios Retrospectivos , Paratiroidectomía/métodos , Radiofármacos , Sensibilidad y Especificidad
7.
J Surg Res ; 296: 547-555, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38340488

RESUMEN

INTRODUCTION: 2%-10% of patients with primary hyperparathyroidism (PHPT) who undergo parathyroidectomy develop persistent/recurrent disease. The aim of this study was to determine which preoperative localization method is most cost-effective in reoperative PHPT. METHODS: Clinical decision analytic models comparing cost-effectiveness of localizing studies in reoperative PHPT were constructed using TreeAge Pro. Cost and probability assumptions were varied via Probabilistic Sensitivity Analysis (PSA) to test the robustness of the base case models. RESULTS: Base case analysis of model 1 revealed ultrasound (US)-guided fine-needle aspiration with PTH assay as most cost-effective after localizing US. This was confirmed on PSA of model 1. Model 2 showed four-dimensional computed tomography (4D-CT) as most cost-effective after negative US. If not localized by US, on PSA, 4D-CT was the next most cost-effective test. CONCLUSIONS: US-guided FNA with PTH is the most cost-effective confirmatory test after US localization. 4D-CT should be considered as the next best test after negative US.


Asunto(s)
Hiperparatiroidismo Primario , Humanos , Hiperparatiroidismo Primario/cirugía , Análisis Costo-Beneficio , Tecnecio Tc 99m Sestamibi , Paratiroidectomía , Tomografía Computarizada Cuatridimensional/métodos , Glándulas Paratiroides/cirugía
8.
J Appl Clin Med Phys ; 25(4): e14257, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38303539

RESUMEN

PURPOSE: To analyze the respiratory-induced motion trajectories of each liver segment for hepatocellular carcinoma (HCC) to derive a more accurate internal margin and optimize treatment protocol selection. MATERIALS AND METHODS: Ten-phase-gated four-dimensional computed tomography (4DCT) scans of 14 patients with HCC were analyzed. For each patient, eight representative regions of interest (ROI) were delineated on each liver segment in all 10 phases. The coordinates of the center of gravity of each ROI were obtained for each phase, and then the respiratory motion in the left-right (LR), anteroposterior (AP), and craniocaudal (CC) directions was analyzed. Two sets of motion in each direction were also compared in terms of only two extreme phases and all 10 phases. RESULTS: Motion of less than 5 mm was detected in 12 (86%) and 10 patients (71%) in the LR and AP directions, respectively, while none in the CC direction. Motion was largest in the CC direction with a maximal value of 19.5 mm, with significant differences between liver segment 7 (S7) and other segments: S1 (p < 0.036), S2 (p < 0.041), S3 (p < 0.016), S4 (p < 0.041), and S5 (p < 0.027). Of the 112 segments, hysteresis >1 mm was observed in 4 (4%), 2 (2%), and 15 (13%) in the LR, AP, and CC directions, respectively, with a maximal value of 5.0 mm in the CC direction. CONCLUSION: A significant amount of respiratory motion was detected in the CC direction, especially in S7, and S8. Despite the small effect of hysteresis, it can be observed specifically in the right lobe. Therefore, caution is required when using 4DCT to determine IM using only end-inspiration and end-expiration. Understanding the respiratory motion in individual liver segments can be helpful when selecting an appropriate treatment protocol.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patología , Movimiento (Física) , Respiración , Tomografía Computarizada Cuatridimensional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
9.
Comput Methods Programs Biomed ; 244: 107998, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38176330

RESUMEN

BACKGROUND AND OBJECTIVE: Estimating the three-dimensional (3D) deformation of the lung is important for accurate dose delivery in radiotherapy and precise surgical guidance in lung surgery navigation. Additional 4D-CT information is often required to eliminate the effect of individual variations and obtain a more accurate estimation of lung deformation. However, this results in increased radiation dose. Therefore, we propose a novel method that estimates lung tissue deformation from depth maps and two CT phases per patient. METHODS: The method models the 3D motion of each voxel as a linear displacement along a direction vector, with a variable amplitude and phase that depend on the voxel location. The direction vector and amplitude are derived from the registration of the CT images at the end-of-exhale (EOE) and the end-of-inhale (EOI) phases. The voxel phase is estimated by a neural network. Coordinate convolution (CoordConv) is used to fuse multimodal data and embed absolute position information. The network takes the front and side views as well as the previous phase views as inputs to enhance accuracy. RESULTS: We evaluate the proposed method on two datasets: DIR-Lab and 4D-Lung, and obtain average errors of 2.11 mm and 1.36 mm, respectively. The method achieves real-time performance of less than 7 ms per frame on a NVIDIA GeForce 2080Ti GPU. CONCLUSION: Compared with previous methods, our method achieves comparable or even better accuracy with less CT phases.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Pulmón/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/métodos , Redes Neurales de la Computación , Tórax , Respiración
10.
Med Phys ; 51(1): 579-590, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37166067

RESUMEN

BACKGROUND: Numerical 4D phantoms, together with associated ground truth motion, offer a flexible and comprehensive data set for realistic simulations in radiotherapy and radiology in target sites affected by respiratory motion. PURPOSE: We present an openly available upgrade to previously reported methods for generating realistic 4DCT lung numerical phantoms, which now incorporate respiratory ribcage motion and improved lung density representation throughout the breathing cycle. METHODS: Density information of reference CTs, toget her with motion from multiple breathing cycle 4DMRIs have been combined to generate synthetic 4DCTs (4DCT(MRI)s). Inter-subject correspondence between the CT and MRI anatomy was first established via deformable image registration (DIR) of binary masks of the lungs and ribcage. Ribcage and lung motions were extracted independently from the 4DMRIs using DIR and applied to the corresponding locations in the CT after post-processing to preserve sliding organ motion. In addition, based on the Jacobian determinant of the resulting deformation vector fields, lung densities were scaled on a voxel-wise basis to more accurately represent changes in local lung density. For validating this process, synthetic 4DCTs, referred to as 4DCT(CT)s, were compared to the originating 4DCTs using motion extracted from the latter, and the dosimetric impact of the new features of ribcage motion and density correction were analyzed using pencil beam scanned proton 4D dose calculations. RESULTS: Lung density scaling led to a reduction of maximum mean lung Hounsfield units (HU) differences from 45 to 12 HU when comparing simulated 4DCT(CT)s to their originating 4DCTs. Comparing 4D dose distributions calculated on the enhanced 4DCT(CT)s to those on the original 4DCTs yielded 2%/2 mm gamma pass rates above 97% with an average improvement of 1.4% compared to previously reported phantoms. CONCLUSIONS: A previously reported 4DCT(MRI) workflow has been successfully improved and the resulting numerical phantoms exhibit more accurate lung density representations and realistic ribcage motion.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Pulmón/diagnóstico por imagen , Radiometría/métodos , Respiración , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos
11.
J Appl Clin Med Phys ; 25(2): e14174, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37815197

RESUMEN

Four-dimensional computed tomography (4DCT), which relies on breathing-induced motion, requires realistic surrogate information of breathing variations to reconstruct the tumor trajectory and motion variability of normal tissues accurately. Therefore, the SimRT surface-guided respiratory monitoring system has been installed on a Siemens CT scanner. This work evaluated the temporal and spatial accuracy of SimRT versus our commonly used pressure sensor, AZ-733 V. A dynamic thorax phantom was used to reproduce regular and irregular breathing patterns acquired by SimRT and Anzai. Various parameters of the recorded breathing patterns, including mean absolute deviations (MAD), Pearson correlations (PC), and tagging precision, were investigated and compared to ground-truth. Furthermore, 4DCT reconstructions were analyzed to assess the volume discrepancy, shape deformation and tumor trajectory. Compared to the ground-truth, SimRT more precisely reproduced the breathing patterns with a MAD range of 0.37 ± 0.27 and 0.92 ± 1.02 mm versus Anzai with 1.75 ± 1.54 and 5.85 ± 3.61 mm for regular and irregular breathing patterns, respectively. Additionally, SimRT provided a more robust PC of 0.994 ± 0.009 and 0.936 ± 0.062 for all investigated breathing patterns. Further, the peak and valley recognition were found to be more accurate and stable using SimRT. The comparison of tumor trajectories revealed discrepancies up to 7.2 and 2.3 mm for Anzai and SimRT, respectively. Moreover, volume discrepancies up to 1.71 ± 1.62% and 1.24 ± 2.02% were found for both Anzai and SimRT, respectively. SimRT was validated across various breathing patterns and showed a more precise and stable breathing tracking, (i) independent of the amplitude and period, (ii) and without placing any physical devices on the patient's body. These findings resulted in a more accurate temporal and spatial accuracy, thus leading to a more realistic 4DCT reconstruction and breathing-adapted treatment planning.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/cirugía , Respiración , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador , Planificación de la Radioterapia Asistida por Computador/métodos
12.
J Appl Clin Med Phys ; 25(1): e14211, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37992226

RESUMEN

BACKGROUND: The location and morphology of the liver are significantly affected by respiratory motion. Therefore, delineating the gross target volume (GTV) based on 4D medical images is more accurate than regular 3D-CT with contrast. However, the 4D method is also more time-consuming and laborious. This study proposes a deep learning (DL) framework based on 4D-CT that can achieve automatic delineation of internal GTV. METHODS: The proposed network consists of two encoding paths, one for feature extraction of adjacent slices (spatial slices) in a specific 3D-CT sequence, and one for feature extraction of slices at the same location in three adjacent phase 3D-CT sequences (temporal slices), a feature fusion module based on an attention mechanism was proposed for fusing the temporal and spatial features. Twenty-six patients' 4D-CT, each consisting of 10 respiratory phases, were used as the dataset. The Hausdorff distance (HD95), Dice similarity coefficient (DSC), and volume difference (VD) between the manual and predicted tumor contour were computed to evaluate the model's segmentation accuracy. RESULTS: The predicted GTVs and IGTVs were compared quantitatively and visually with the ground truth. For the test dataset, the proposed method achieved a mean DSC of 0.869 ± 0.089 and an HD95 of 5.14 ± 3.34 mm for all GTVs, with under-segmented GTVs on some CT slices being compensated by GTVs on other slices, resulting in better agreement between the predicted IGTVs and the ground truth, with a mean DSC of 0.882 ± 0.085 and an HD95 of 4.88 ± 2.84 mm. The best GTV results were generally observed at the end-inspiration stage. CONCLUSIONS: Our proposed DL framework for tumor segmentation on 4D-CT datasets shows promise for fully automated delineation in the future. The promising results of this work provide impetus for its integration into the 4DCT treatment planning workflow to improve hepatocellular carcinoma radiotherapy.


Asunto(s)
Carcinoma Hepatocelular , Aprendizaje Profundo , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patología , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patología , Carga Tumoral
13.
Radiol Phys Technol ; 17(1): 143-152, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37930563

RESUMEN

This study focused on the dosimetric impact of variations in respiratory motion during lung stereotactic body radiotherapy (SBRT). Dosimetric comparisons between volumetric modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3DCRT) were performed using four-dimensional computed tomography (4DCT)-based internal target volumes (ITV). We created retrospective plans for ten patients with lung cancer who underwent SBRT using 3DCRT and VMAT techniques. A Delta4 Phantom + (ScandiDos, Uppsala, Sweden) was used to evaluate the dosimetric robustness of 4DCT-based ITV against variations in respiratory motion during treatment. We analyzed respiratory motion during treatment. Dose-volume histogram parameters were evaluated for the 95% dose (D95%) to the planning target volume (PTV) contoured on CT images obtained under free breathing. The correlations between patient respiratory parameters and dosimetric errors were also evaluated. In the phantom study, the average PTV D95% dose differences for all fractions were - 2.9 ± 4.4% (- 16.0 - 1.2%) and - 2.0 ± 2.8% (- 11.2 - 0.7%) for 3DCRT and VMAT, respectively. The average dose difference was < 3% for both 3DCRT and VMAT; however, in 5 out of 42 fractions in 3DCRT, the difference in PTV D95% was > 10%. Dosimetric errors were correlated with respiratory amplitude and velocity, and differences in respiratory amplitude between 4DCT and treatment days were the main factors causing dosimetric errors. The overall average dose error of the PTV D95% was small; however, both 3DCRT and VMAT cases exceeding 10% error were observed. Larger errors occurred with amplitude variation or baseline drift, indicating limited robustness of 4DCT-based ITV.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada Cuatridimensional/métodos , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Pulmón , Dosificación Radioterapéutica
14.
Med Phys ; 51(1): 566-578, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37672227

RESUMEN

PURPOSE: We developed a 4-dimensional dynamic dose (4DDD) calculation model for proton pencil beam scanning (PBS). This model incorporates the spill start time for all energies and uses the remaining irradiated spot time model instead of irradiated spot time logs. This study aimed to validate the calculation accuracy of a log file-based 4DDD model by comparing it with dose measurements performed under free-breathing conditions, thereby serving as an alternative approach to the conventional log file-based system. METHODS: Three cubic verification plans were created using a heterogeneous block phantom; these plans were created using 10 phase 4D-CT datasets of the phantom. The CIRS dynamic platform was used to simulate motion with amplitudes of 2.5, 3.75, and 5.0 mm. These plans consisted of eight- and two-layered rescanning techniques. The lateral profiles were measured using a 2D ionization chamber array (2D-array) and EBT3 Gafchromic films at four starting phases, including three sinusoidal curves (periods of 3, 4, and 6 s) and a representative patient curve during actual treatment. 4DDDs were calculated using in-house scripting that assigned a time stamp to each spot and performed dose accumulation using deformable image registration. Furthermore, to evaluate the impact of parameter selection on our 4DDD model calculations, simulations were performed assuming a ±10% change in irradiation time stamp (0.8 ± 0.08 s) and spot scan speed. We evaluated the 2D gamma index and the absolute point doses between the calculated values and the measurements. RESULTS: The 2D-array measurements revealed that the gamma scores for the static plans (no motion) and 4DDD plans exceeded 97.5% and 93.9% at 3%/3 mm, respectively. The average gamma score of the 4DDD plans was at least 96.1%. When using EBT3 films, the gamma scores of the 4DDD model exceeded 92.4% and 98.7% at 2%/2 mm and 3%/3 mm, respectively. Regarding the 4DDD point dose differences, more than 95% of the dose regions exhibited discrepancies within ±5.0% for 97.7% of the total points across all plans. The spot time assignment accuracy of our 4DDD model was acceptable even with ±10% sensitivity. However, the accuracy of the scan speed, when varied within ±10% sensitivity, was not acceptable (minimum gamma scores of 82.6% and maximum dose difference of 12.9%). CONCLUSIONS: Our 4DDD calculations under free-breathing conditions using amplitudes of less than 5.0 mm were in good agreement with the measurements regardless of the starting phases, breathing curve patterns (between 3 and 6 s periods), and varying numbers of layered rescanning. The proposed system allows us to evaluate actual irradiated doses in various breathing periods, amplitudes, and starting phases, even on PBS machines without the ability to record spot logs.


Asunto(s)
Terapia de Protones , Protones , Humanos , Respiración , Terapia de Protones/métodos , Movimiento (Física) , Tomografía Computarizada Cuatridimensional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica
15.
Med Phys ; 51(2): 1364-1382, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37427751

RESUMEN

BACKGROUND: The adoption of four-dimensional cone beam computed tomography (4DCBCT) for image-guided lung cancer radiotherapy is increasing, especially for hypofractionated treatments. However, the drawbacks of 4DCBCT include long scan times (∼240 s), inconsistent image quality, higher imaging dose than necessary, and streaking artifacts. With the emergence of linear accelerators that can acquire 4DCBCT scans in a short period of time (9.2 s) there is a need to examine the impact that these very fast gantry rotations have on 4DCBCT image quality. PURPOSE: This study investigates the impact of gantry velocity and angular separation between x-ray projections on image quality and its implication for fast low-dose 4DCBCT with emerging systems, such as the Varian Halcyon that provide fast gantry rotation and imaging. Large and uneven angular separation between x-ray projections is known to reduce 4DCBCT image quality through increased streaking artifacts. However, it is not known when angular separation starts degrading image quality. The study assesses the impact of constant and adaptive gantry velocity and determines the level when angular gaps impair image quality using state-of-the-art reconstruction methods. METHODS: This study considers fast low-dose 4DCBCT acquisitions (60-80 s, 200-projection scans). To assess the impact of adaptive gantry rotations, the angular position of x-ray projections from adaptive 4DCBCT acquisitions from a 30-patient clinical trial were analyzed (referred to as patient angular gaps). To assess the impact of angular gaps, variable and static angular gaps (20°, 30°, 40°) were introduced into evenly separated 200 projections (ideal angular separation). To simulate fast gantry rotations, which are on emerging linacs, constant gantry velocity acquisitions (9.2 s, 60 s, 120 s, 240 s) were simulated by sampling x-ray projections at constant intervals using the patient breathing traces from the ADAPT clinical trial (ACTRN12618001440213). The 4D Extended Cardiac-Torso (XCAT) digital phantom was used to simulate projections to remove patient-specific image quality variables. Image reconstruction was performed using Feldkamp-Davis-Kress (FDK), McKinnon-Bates (MKB), and Motion-Compensated-MKB (MCMKB) algorithms. Image quality was assessed using Structural Similarity-Index-Measure (SSIM), Contrast-to-Noise-Ratio (CNR), Signal-to-Noise-Ratio (SNR), Tissue-Interface-Width-Diaphragm (TIW-D), and Tissue-Interface-Width-Tumor (TIW-T). RESULTS: Patient angular gaps and variable angular gap reconstructions produced similar results to ideal angular separation reconstructions, while static angular gap reconstructions produced lower image quality metrics. For MCMKB-reconstructions, average patient angular gaps produced SSIM-0.98, CNR-13.6, SNR-34.8, TIW-D-1.5 mm, and TIW-T-2.0 mm, static angular gap 40° produced SSIM-0.92, CNR-6.8, SNR-6.7, TIW-D-5.7 mm, and TIW-T-5.9 mm and ideal produced SSIM-1.00, CNR-13.6, SNR-34.8, TIW-D-1.5 mm, and TIW-T-2.0 mm. All constant gantry velocity reconstructions produced lower image quality metrics than ideal angular separation reconstructions regardless of the acquisition time. Motion compensated reconstruction (MCMKB) produced the highest contrast images with low streaking artifacts. CONCLUSION: Very fast 4DCBCT scans can be acquired provided that the entire scan range is adaptively sampled, and motion-compensated reconstruction is performed. Importantly, the angular separation between x-ray projections within each individual respiratory bin had minimal effect on the image quality of fast low-dose 4DCBCT imaging. The results will assist the development of future 4DCBCT acquisition protocols that can now be achieved in very short time frames with emerging linear accelerators.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Fantasmas de Imagen , Relación Señal-Ruido , Técnicas de Imagen Sincronizada Respiratorias/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
16.
IEEE Trans Med Imaging ; 43(2): 784-793, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37782589

RESUMEN

Recent works in medical image registration have proposed the use of Implicit Neural Representations, demonstrating performance that rivals state-of-the-art learning-based methods. However, these implicit representations need to be optimized for each new image pair, which is a stochastic process that may fail to converge to a global minimum. To improve robustness, we propose a deformable registration method using pairs of cycle-consistent Implicit Neural Representations: each implicit representation is linked to a second implicit representation that estimates the opposite transformation, causing each network to act as a regularizer for its paired opposite. During inference, we generate multiple deformation estimates by numerically inverting the paired backward transformation and evaluating the consensus of the optimized pair. This consensus improves registration accuracy over using a single representation and results in a robust uncertainty metric that can be used for automatic quality control. We evaluate our method with a 4D lung CT dataset. The proposed cycle-consistent optimization method reduces the optimization failure rate from 2.4% to 0.0% compared to the current state-of-the-art. The proposed inference method improves landmark accuracy by 4.5% and the proposed uncertainty metric detects all instances where the registration method fails to converge to a correct solution. We verify the generalizability of these results to other data using a centerline propagation task in abdominal 4D MRI, where our method achieves a 46% improvement in propagation consistency compared with single-INR registration and demonstrates a strong correlation between the proposed uncertainty metric and registration accuracy.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Pulmón , Tomografía Computarizada Cuatridimensional/métodos , Pulmón/diagnóstico por imagen , Tórax , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
17.
J Radiat Res ; 65(1): 100-108, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38037473

RESUMEN

The Pencil Beam Scanning (PBS) technique in modern particle therapy offers a highly conformal dose distribution but poses challenges due to the interplay effect, an interaction between respiration-induced organ movement and PBS. This study evaluates the effectiveness of different volumetric rescanning strategies in mitigating this effect in liver cancer proton therapy. We used a Geant4-based Monte Carlo simulation toolkit, 'TOPAS,' and an image registration toolbox, 'Elastix,' to calculate 4D dose distributions from 5 patients' four-dimensional computed tomography (4DCT). We analyzed the homogeneity index (HI) value of the Clinical Tumor Volume (CTV) at different rescan numbers and treatment times. Our results indicate that dose homogeneity stabilizes at a low point after a week of treatment, implying that both rescanning and fractionation treatments help mitigate the interplay effect. Notably, an increase in the number of rescans doesn't significantly reduce the mean dose to normal tissue but effectively prevents high localized doses to tissue adjacent to the CTV. Rescanning techniques, based on statistical averaging, require no extra equipment or patient cooperation, making them widely accessible. However, the number of rescans, tumor location, diaphragm movement, and treatment fractionation significantly influence their effectiveness. Therefore, deciding the number of rescans should involve considering the number of beams, treatment fraction size, and total delivery time to avoid unnecessary treatment extension without significant clinical benefits. The results showed that 2-3 rescans are more clinically suitable for liver cancer patients undergoing proton therapy.


Asunto(s)
Neoplasias Hepáticas , Terapia de Protones , Humanos , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Fraccionamiento de la Dosis de Radiación , Movimiento , Dosificación Radioterapéutica , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Hepáticas/radioterapia
18.
Phys Med Biol ; 69(2)2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38091611

RESUMEN

Objective.As the most common solution to motion artefact for cone-beam CT (CBCT) in radiotherapy, 4DCBCT suffers from long acquisition time and phase sorting error. This issue could be addressed if the motion at each projection could be known, which is a severely ill-posed problem. This study aims to obtain the motion at each time point and motion-free image simultaneously from unsorted projection data of a standard 3DCBCT scan.Approach.Respiration surrogate signals were extracted by the Intensity Analysis method. A general framework was then deployed to fit a surrogate-driven motion model that characterized the relation between the motion and surrogate signals at each time point. Motion model fitting and motion compensated reconstruction were alternatively and iteratively performed. Stochastic subset gradient based method was used to significantly reduce the computation time. The performance of our method was comprehensively evaluated through digital phantom simulation and also validated on clinical scans from six patients.Results.For digital phantom experiments, motion models fitted with ground-truth or extracted surrogate signals both achieved a much lower motion estimation error and higher image quality, compared with non motion-compensated results.For the public SPARE Challenge datasets, more clear lung tissues and less blurry diaphragm could be seen in the motion compensated reconstruction, comparable to the benchmark 4DCBCT images but with a higher temporal resolution. Similar results were observed for two real clinical 3DCBCT scans.Significance.The motion compensated reconstructions and motion models produced by our method will have direct clinical benefit by providing more accurate estimates of the delivered dose and ultimately facilitating more accurate radiotherapy treatments for lung cancer patients.


Asunto(s)
Algoritmos , Tomografía Computarizada Cuatridimensional , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Movimiento (Física) , Tomografía Computarizada de Haz Cónico/métodos , Respiración , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos
19.
Int J Radiat Oncol Biol Phys ; 118(1): 231-241, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37552151

RESUMEN

PURPOSE: The aim of this study was to investigate the dosimetric and clinical effects of 4-dimensional computed tomography (4DCT)-based longitudinal dose accumulation in patients with locally advanced non-small cell lung cancer treated with standard-fractionated intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS: Sixty-seven patients were retrospectively selected from a randomized clinical trial. Their original IMRT plan, planning and verification 4DCTs, and ∼4-month posttreatment follow-up CTs were imported into a commercial treatment planning system. Two deformable image registration algorithms were implemented for dose accumulation, and their accuracies were assessed. The planned and accumulated doses computed using average-intensity images or phase images were compared. At the organ level, mean lung dose and normal-tissue complication probability (NTCP) for grade ≥2 radiation pneumonitis were compared. At the region level, mean dose in lung subsections and the volumetric overlap between isodose intervals were compared. At the voxel level, the accuracy in estimating the delivered dose was compared by evaluating the fit of a dose versus radiographic image density change (IDC) model. The dose-IDC model fit was also compared for subcohorts based on the magnitude of NTCP difference (|ΔNTCP|) between planned and accumulated doses. RESULTS: Deformable image registration accuracy was quantified, and the uncertainty was considered for the voxel-level analysis. Compared with planned doses, accumulated doses on average resulted in <1-Gy lung dose increase and <2% NTCP increase (up to 8.2 Gy and 18.8% for a patient, respectively). Volumetric overlap of isodose intervals between the planned and accumulated dose distributions ranged from 0.01 to 0.93. Voxel-level dose-IDC models demonstrated a fit improvement from planned dose to accumulated dose (pseudo-R2 increased 0.0023) and a further improvement for patients with ≥2% |ΔNTCP| versus for patients with <2% |ΔNTCP|. CONCLUSIONS: With a relatively large cohort, robust image registrations, multilevel metric comparisons, and radiographic image-based evidence, we demonstrated that dose accumulation more accurately represents the delivered dose and can be especially beneficial for patients with greater longitudinal response.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radioterapia de Intensidad Modulada , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Estudios Retrospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada Cuatridimensional/métodos
20.
Endocr Pract ; 30(3): 239-245, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38122932

RESUMEN

OBJECTIVE: To investigate the usefulness of ultrasound (US) for the localization of ectopic hyperparathyroidism and compare it with 99mTc-sestamibi (99mTc-MIBI), 4-dimensional computed tomography (4D-CT), and 11C-choline positron emission tomography/ computed tomography (PET/CT). METHODS: Of the 527 patients with surgically confirmed primary hyperparathyroidism, 79 patients with ectopic hyperparathyroidism were enrolled. The diagnostic performance of US, 99mTc-MIBI, US + MIBI, 4D-CT, and 11C-choline PET/CT was calculated, and the factors affecting the sensitivity of US and 99mTc-MIBI were analyzed. RESULTS: Eighty-three ectopic parathyroid lesions were found in 79 patients. The sensitivity was 75.9%, 81.7%, 95.1%, 83.3%, and 100% for US, 99mTc-MIBI, US + MIBI, 4D-CT, and 11C-choline PET/CT, respectively. The difference in sensitivity among these different modalities did not achieve statistical significance (P > .05). The US sensitivity was significantly higher for ectopic lesions in the neck region than for those in the anterior mediastinum/chest wall (85.9% vs. 42.1%, P < .001). The 99mTc-MIBI and 4D-CT sensitivity was not significantly different between these two groups (84.1% vs. 94.6%, P = .193 and 81.3% vs. 85.7%, P = 1). The 11C-choline PET/CT sensitivity was 100% in both groups. CONCLUSIONS: US is a valuable tool for the localization of ectopic hyperparathyroidism, especially for ectopic lesions in the neck region.


Asunto(s)
Hiperparatiroidismo Primario , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada Cuatridimensional/métodos , Hiperparatiroidismo Primario/diagnóstico por imagen , Colina , Tecnecio Tc 99m Sestamibi , Glándulas Paratiroides/diagnóstico por imagen , Radiofármacos
SELECCIÓN DE REFERENCIAS